KASEEY electrical busbars, circuit breakers and distribution products

Comb Busbar
Manufacturer

Pin and fork comb busbars, connection accessories and terminal components for panel builders, distributors and OEM programs. Confirm the right model with our manufacturing team.

Explore Product Categories
TÜV mark
CCCI mark
RoHS mark
SGS mark
CE mark
PONY mark
VDE mark
REACH mark

Complete Busbar
Product Range

Explore eleven coordinated categories covering busbars, connectors, protective covers, wiring bridges, copper and brass distribution products, terminal block boxes and DIN rails—plus custom busbar development for project and OEM requirements.

COMPLETE PRODUCT MATRIX

All 10 KASEEY Connection Families

Four integrated electrical connection systems—modular comb busbars, pan assemblies, neutral/earth brass hardware, and custom OEM copper bars—manufactured under one roof since 2007.

Browse All Products →
KASEEY Electrical Connection & Busbar Specification Overview
Product Family Key Specifications Current / Material Primary Panel Application Category
Pin-Type Comb Busbars (P-1L / C45) 1P, 2P, 3P, 4P, 1P+N · 17.8 mm pitch · 210 / 1000 / 1016 mm 50 A – 80 A · 8–16 mm² Electrolytic Copper Modular MCB & RCBO box-clamp (cage) terminals View Series
Fork-Type Comb Busbars (M5.5 / M6 / Closed) 1P, 2P, 3P, 4P, 3L+3N · 17.8 mm pitch · Open & closed profiles Up to 100 A · 10–25 mm² Electrolytic Copper Seats under screw head, leaving cable cage open View Series
Pan Assembly Busbars (KP-125A / KP-250A) Factory-assembled 12-way to 60-way vertical distribution interiors 125 A – 250 A · Shrouded Copper Chassis Commercial IEC 61439-3 distribution boards View Series
Busbar End Caps (EK1-4 / EK3-10D) 1P to 4P & closed-profile snap-on insulating end caps Flame-Retardant Insulating Polymer Restores IP20 touch safety & creepage after cutting View Series
Busbar Protective Covers (COV-1-2) Snap-on insulating tooth shrouds for unused ways High-Visibility Insulating Polymer Protects spare comb busbar teeth against touch View Series
Feed-In Connectors & Terminals (TB25 / TB50) 25 mm² & 50 mm² incoming feed terminals + crimp terminals High-Current Brass/Copper Feed Blocks End-feed or center-feed incoming cable entry View Series
Modular Wiring Bridges (WB2 / WB3 / WB4) Pre-insulated multi-pole row-to-row jumper bridges Insulated Flexible Copper Conductors Links adjacent DIN-rail rows or mismatched planes View Series
Solid Copper & Brass Bars (KB / T15) Flat, punched, tinned & custom-machined bars Electrolytic Copper / Multi-Hole Brass Main switchboard feeders, neutral (N) & earth (PE) Copper · Brass
Brass Terminal Blocks & Boxes (T001–T005) Multi-way screw-clamp N/PE bars & distribution boxes Brass Conductors + Insulated Supports Segregated neutral & earth panel distribution Blocks · Boxes
Steel & Aluminum DIN Rails (TH35-7.5 / TH35-15) 35 mm IEC 60715 top-hat rails, slotted & unslotted Galvanized Steel & Extruded Aluminum Standard modular switchgear & terminal mounting View Series

Electrical Focus,
Manufacturing
Since 2007

Yueqing Kaseey Electric Co., Ltd. is an electrical connection component manufacturer integrating R&D, production and sales.

From our Yueqing production base, we support customers with product consultation, development, organized manufacturing and dependable delivery.

Explore Manufacturing
Founded
Countries served
Business partners
Product categories
BUSBAR SOLUTIONS

Four systems for a more complete connection.

Start with the device interface or distribution task, then review the matching busbar, supporting parts and supply requirements.

Explore all solutions
Modular Device Busbar Systems
01 / 04

Modular Device Busbar Systems

Pin, fork and closed busbars matched to MCB, RCCB and RCBO terminal platforms.

View solution
INTERACTIVE INTERFACE MATCHER

Match Terminal Profile, Feed Point & Area

Select your modular terminal interface, phase sequence, incoming feed point, and target load current to identify the right KASEEY busbar series and matching accessories.

End Feed vs. Center Feed Current Distribution (16 mm² Comb Busbar)

IEC 61439 Thermal Split Reference
END FEED (16 mm² Bar · Single Path ≤ 80 A) 100% row current passes first span Thermal load concentrates at incoming terminal end. CENTER FEED (Parallel Left & Right Branch Split) ◀ Left Branch Right Branch ▶ Splits feeder current into two paths—verify datasheet center-feed limit.

Verified Copper Cross-Section

Full-gauge electrolytic copper strips prevent excessive temperature rise under continuous panel loads and protect adjacent thermal breaker elements.

Controlled Stamping Pitch

Progressive stamping maintains consistent 17.8 mm pitch across 12 to 57 module bars, preventing cumulative pitch walk and skewed terminal clamps.

Complete Touch-Safe Finishing

Pair cuttable bars with EK End Caps, COV Tooth Covers, and TB25/TB50 Feed Connectors for IEC 61439 IP20 compliance.

OEM / ODM WORKFLOW

From your requirement to repeat production.

Build a defined supply program around the product specification, market presentation and purchasing plan.

Explore OEM / ODM
  1. 01

    Requirement review

    Confirm the product family, electrical ratings, target market and expected order volume.

  2. 02

    Configuration & sample

    Align product options and prepare samples or controlled references for approval.

  3. 03

    Brand & packaging

    Review private labeling, markings, packaging and supporting documentation.

  4. 04

    Production & inspection

    Release the confirmed specification into controlled production and final inspection.

  5. 05

    Repeat B2B supply

    Use the approved order reference for replenishment and future range development.

B2B PROCUREMENT

Clear information before you place an order.

Commercial terms depend on the product, quantity and customization scope. KASEEY confirms the practical details in the quotation instead of publishing assumptions.

01

MOQ & samples

Confirm sample availability and minimum order quantity for the selected model.

02

Lead time

Receive a production estimate based on quantity, materials and OEM requirements.

03

Packaging options

Review standard export packaging, private-label presentation and carton markings.

04

Technical documents

Request datasheets, drawings and available compliance documents for the order reference.

5-STEP RFQ SPEC BUILDER

Build Your Busbar Inquiry Brief

Select your target hardware family, cross-section, length format, and OEM branding requirements to copy a structured specification brief directly into your quotation request.

Partners

Trusted by Enterprises Around the World

Collaborating for a stronger electrical supply future

150+

Global Business Partners

MEET KASEEY

Connect with us at industry exhibitions.

CATALOG & TECHNICAL DOCUMENTS

Give your engineering and purchasing teams the right files.

Browse available resources or request the controlled document matched to your selected model and market.

PRODUCT INFORMATIONCatalogs & datasheetsCOMPLIANCECertificates & standards

News & Insights

TECHNICAL & OEM FAQ

Busbar Selection & Supply Questions

Direct engineering answers for panel builders, switchgear assemblers, and OEM procurement teams.

View All 40+ FAQs →
When should I specify a Pin-Type versus a Fork-Type comb busbar?
Pin-type comb busbars insert directly into box-clamp (cage) breaker terminals—ideal for modular MCBs and RCBOs without separate fork slots. Fork-type comb busbars seat under the terminal screw head, leaving the main cage chamber open for incoming or outgoing cables. See our Pin vs Fork Busbar Guide.
How does Center Feed improve current capacity compared with End Feed?
Feeding a comb busbar from one end sends 100% of total row current through the first copper span (for example, up to 80 A on a 16 mm² P-1L bar). Moving the feeder to the center splits current into left and right parallel branches, reducing localized heating while staying within the verified center-feed limit.
Why are insulating end caps mandatory after cutting a 1-meter comb busbar?
Cutting an open-ended comb busbar exposes bare live copper at the cut face, reducing inter-phase creepage and clearance under IEC 61439. Always deburr the cut, maintain insulating setback, and install matched KASEEY EK End Caps to restore IP20 finger-safe protection.
How do I confirm comb busbar fit for my specific modular breaker row?
Verify four physical coordinates against your breaker terminal drawing before ordering: pole pitch (17.8 mm vs 18.0 mm, or 45/54/63 mm for GV2-footprint motor starters), pin-versus-fork clamp style, terminal throat depth, and phase/neutral sequence (1P+N, 3P, 3L+3N, or 4P). For non-standard rows, KASEEY produces drawing-led custom profiles via Custom Busbar OEM.
Can KASEEY supply pre-cut lengths, private-label marking, and consolidated panel kits?
Yes. Alongside standard 210 mm, 1000 mm, and 1016 mm comb busbars, KASEEY supports custom pre-cut module counts, OEM part-number marking, and consolidated shipments combining comb busbars, pan assemblies, end caps, protective covers, copper/brass bars, brass terminal blocks, and DIN rails.
KASEEY comb busbars and electrical connection product range

Need the right busbar for your application?

Share your device model, terminal type, required dimensions and order quantity. Our team will help confirm a suitable configuration and quotation.